PH Meter

PH Meter
Product Detailed
Related Categories:Testing Equipment
Related Product Searches:PH Meter,High Quality pen ph meter,pen ph meter AH-ORP
PH meter Range : 0.00to 14.00 pH Resolution : 0.01 pH Accuracy : 0.05 pH Batteries : 4 x 1.5V

PH meter

SPECIFICATIONS    Range : 0.00to 14.00 pH    Resolution : 0.01 pH    Accuracy : ±0.05 pH    Batteries : 4 x 1.5V alkaline    ATC: 0°C to 60°C    Environment : RH 95% max; 0 to 60°C     Dimensions : 172x26x26mm    Weight : 73 g     OPERATION    •Remove the protective cap. Do not be alarmed if white crystals     appear around the cap. This is normal with pH electrodes and     they dissolve when rinsed with water.    •Turn the tester ON by pressing the 'ON/OFF' button.     •Immerse into solution up to the max immersion level.    •Stir gently and wait until the display stabilizes.    •After use, Turn the tester off by pressing the 'ON/OFF' button,    use the water clean the electrode and replace the protective cap.    Do not use distilled or deionized water for storage purposes.    •Large fluctuations in readings could be due to lack of calibration,     dry electrode or rundown batteries.    CALIBRATION    •Immerse the tester up to the maximum immersion level in pH 6.86 buffer solution.    •Allow the reading to stabilize and using a small screwdriver adjust the calibration trimmer to read 6.86    •Immerse the electrode in PH4.01 or PH9.18 the standard buffer solution of borax. Until the display    shows '3.96-4.06PH'or'9.13-9.23PH'    Always use fresh buffers for calibration.    Important The instrument must be re-calibrated whenever.    •The electrode or battery has been replaced.    •Approximately one mouth has passed from the last calibration.    •The electrode has been used in particularly taxing conditions.    •The utmost accuracy is required.     BATTERY REPLACEMENT    When the battery symbol -----appears on the display, this indicates a low battery and only 1 hour    of continuous use remain. though the unit may continue to function ,the accuracy of the unit will be     affected beyond the 1 hour.twist open the battery compartment lid. remove old batteries and replace     with fresh ones noting polarity as show in battery compartment.    ELECTRODE REPLACEMENT    1.Remove the protective cap.    2.Unscrew the plastic ring on the top of the electrode .    3.Pull out the electrode and replace it with a new one. make sure the gaskets are in place before screwing    back the ring.

Other products


Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.